• Users Online: 104
  • Print this page
  • Email this page
REVIEW ARTICLE
Year : 2017  |  Volume : 26  |  Issue : 3  |  Page : 231-234

Comparison of two different ways of passing urethral catheter after transurethral resection of the prostate


Division of Urology, Surgery Department, Jos University Teaching Hospital, Jos, Nigeria

Correspondence Address:
I C Akpayak
Division of Urology, Surgery Department Jos University Teaching Hospital Jos
Nigeria
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/1115-2613.278845

Rights and Permissions

OBJECTIVES: To determine and compare the rate of success of two methods of passing urethral catheter following TURP using silicone Foley catheter: passing the urethral catheter with introducer into an empty bladder and passing the catheter without introducer into bladder filled with normal saline. PATIENTS AND METHODS: This was a prospective study carried out between October, 2013 and November,2016 on 64 patients. Patients who had TURP for BPH where divided into 2 groups based on method of passing urethral catheter after the procedure:Group A: passing silicone urethral catheter with introducer into an empty bladder after TURP. Group B: passing silicone urethral catheter without introducer with bladder filled with normal saline. The outcomes of comparing the groups were computed using appropriate statistical tools. RESULTS: Catheter was passed at single attempt for 15 patients in group A and 14 patients in group B. Successful passage of the catheter was achieved at 2 attempts for 7 patients in group A and 13 patients in group B. Whereas success was achieved at 3 attempts for 10 patients in group A and 5 patients in group B. On comparing the success 2 of attempts to pass the catheter in each group, x2 = 0.721, p = 0.396. Fisher exact test also did not reveal any significance,p = 0.286. CONCLUSION: Passing silicone Foley urethral catheter into a bladder filled with normal saline after TURP is as effective as passing the catheter with the aid of introducer and guarantees no further injury to the urethra.


[PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed74    
    Printed3    
    Emailed0    
    PDF Downloaded17    
    Comments [Add]    

Recommend this journal